Click an empty part of the page: the Properties panel shows the settings of the page and of the project. Page settings apply to the open page; project settings apply to every page. The groups can be collapsed.

BACKGROUND (page)​

SettingValuesDefault
TypeSolid Color, Linear Gradient, Radial GradientSolid Color
Color / Start Color, End ColorColorsWhite, black
Angle0–360° (linear gradient)180°
Object themeFollow station theme, Light theme, Dark themeFollow station theme

↩ Reset to default returns to a white background. Object theme sets the colors of the table, list and chart objects on this page; choose Dark theme on a page with a dark background. Layouts, popups and the editor interface are not affected.

SIZE (page)​

SettingValuesDefault
Width, Height100–7,680 × 100–4,320 pxSize of the page
CacheAutomatic, Never (drop when hidden), Always in memoryAutomatic (Page cache)
ScalingFit inside, Shrink only, 1:1 (scroll), StretchFit inside (Pages and page properties)

PROJECT​

SettingValuesDefaultMore
Start pageFirst page (in order) or a pageFirst pageThe page the runtime screen opens without ?page= (Several monitors)
Project colorsAdd / Edit (n)NoneAnimation
Wait timeout, Waiting style, Invalid color, Show unknown mark (?)10 s, Dimmed + …, none, onAppearance without a value or communication
Communication lost color, Communication lost display, Value while communication is lostPink, Dynamic colors, Last known valueAppearance without a value or communication
Default themeSystem (operating system), Light theme, Dark themeSystem
Station theme rulesRules with name, address pattern and themeNoneSeveral monitors
Reject raw colors in scripts (project color names only)On / offOffScripts must use project color names
Color-only stateWarning, ErrorWarningAnimation
Blink rate0.5–4 Hz1 HzAnimation
Equipment appearance styleISA-101 (simple), Mimic (realistic)ISA-101Process objects
State colors (mimic)IEC 60073 (process), ANSI / IEEE (power)IEC 60073Process objects
ModulesElectrificationOff in a new projectElectrical symbols, wires and simulation in the palette, and the topology service; restart the project after a change
Operator language13 languagesEnglishLanguage of the runtime screen when the user has none; also of the alarm texts written by the server, after a restart
Signal detail panelOpen, Lists only, OffOpenWhere the signal detail panel opens: also from object menus and actions, only from lists, or never (Look at the details of a signal)
'Open in editor' in detailOn / offOnOn: the Open in editor button of the signal detail panel is shown to users with the Studio permission. Off: it is never shown on the runtime screen; Open in trend and Manual value… remain

Runtime › Operator dialogs​

A template per operator dialog and a control panel template per switching device type; see Operator dialog templates.

Runtime › Page cache​

The memory thresholds and counts of the page cache; see Page cache and screen subscription.

Map › Sources​

Default base map and the online XYZ and WMS sources; see Map object.

Electrical › Coloring​

Shown when the page has electrical symbols or wires: automatic coloring, palette, source table, voltage levels, appearance, topological interlocking and topological alarms; see Voltage levels, sources and palette and Set the interlock rules.

REFRESH (page)​

SettingValuesDefault
Default0–60,000 ms0 = values are shown as soon as they change; an object with its own Refresh uses that

FONT​

SettingValuesDefault
Font FamilyA fontInherit from project
Use on all pagesOn / offOn when the page has no font of its own; on writes the font to the project

LAYOUT (page)​

Shown when the project has layouts: Show global layout and Page Layout; see Layouts.

ACCESS (page)​

Shown when the project uses authentication: Login Required and the profiles that may open the page; see Page access.

Good to know​

  • Values equal to the default are not written to the project file.